# DO NOT EDIT - This file is being maintained by Chef
# HP Smart Array configuration
-ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/scheduler}="noop"
-ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/nr_requests}="512"
-ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/read_ahead_kb}="4096"
-ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/rq_affinity}="2"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/scheduler}="noop"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/nr_requests}="512"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/rq_affinity}="2"
+
+# Dell PERC H710 tune
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/scheduler}="deadline"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/nr_requests}="512"
+
<% node[:devices].each do |name,device| -%>
# <%= device[:comment] %>
<% end -%>
<% end -%>
+# Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168/8411 PCI Express Gigabit Ethernet Controller
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x10ec", ATTRS{device}=="0x8168", RUN+="/sbin/ethtool -K $name tso off gso off"
+
+# Ethernet controller: Mellanox Technologies MT27710 Family [ConnectX-4 Lx]
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x15b3", ATTRS{device}=="0x1015", RUN+="/sbin/ethtool -G $name rx 8192 tx 8192"
+
+# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet
+# Hewlett-Packard Company NC382i Integrated Multi-port PCI Express Gigabit Server Adapter
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1639", RUN+="/sbin/ethtool -G $name rx 2040"
+# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme II BCM5708 Gigabit Ethernet
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x164c", RUN+="/sbin/ethtool -G $name rx 2040"
+# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
+# Hewlett-Packard Company Ethernet 1Gb 4-port 331i Adapter
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1657", RUN+="/sbin/ethtool -G $name rx 2047"
+# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5721 Gigabit Ethernet PCI Express
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1659", RUN+="/sbin/ethtool -G $name rx 511"
+# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5720 2-port Gigabit Ethernet PCIe
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x165f", RUN+="/sbin/ethtool -G $name rx 2047"
+
+# Ethernet controller: Intel Corporation 82571EB/82571GB Gigabit Ethernet Controller D0/D1 (copper applications)
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x105e", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation 80003ES2LAN Gigabit Ethernet Controller (Copper)
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1096", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation 82575EB Gigabit Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10a7", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
# Disable scatter-gather offload for HP NC362i network controllers
SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10c9", ATTRS{subsystem_vendor}=="0x103c", ATTRS{subsystem_device}=="0x323f", RUN+="/sbin/ethtool -K $name gso off tso off sg off gro off"
-
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10c9", ATTRS{subsystem_vendor}=="0x103c", ATTRS{subsystem_device}=="0x323f", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation 82574L Gigabit Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10d3", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
# Fix Power Saving Bug on Intel 82574L and Intel 82583 network controllers
SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10d3", RUN+="/usr/local/bin/fixeep-82574_83.sh $name"
SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10f6", RUN+="/usr/local/bin/fixeep-82574_83.sh $name"
SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x150c", RUN+="/usr/local/bin/fixeep-82574_83.sh $name"
+# Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10fb", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation 82580 Gigabit Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x150e", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation I350 Gigabit Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1521", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation Ethernet Controller 10-Gigabit X540-AT2
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1528", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation I210 Gigabit Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1533", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation I211 Gigabit Network Connection
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1539", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x157b", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation Ethernet Controller 10G X550T
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1563", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GBASE-T
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1586", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GBASE-T
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x15ff", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation Ethernet Connection I354 (rev 03)
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1f41", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+# Ethernet controller: Intel Corporation Ethernet Connection X722 for 10GBASE-T
+SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x37d2", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
+
# Workaround unreliable Western Digital WD RE3/RE4 disks (ATA only)
# Set sufficent Linux subsystem timeout and fix severe NCQ performance issue
ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD5002ABYS-02B1B0", ATTR{device/timeout}="90", ATTR{device/queue_depth}="1", ATTR{queue/nr_requests}="256"
ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST31000340NS", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}"
ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="HGST_HTS725050A7E630", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}"
ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="HGST_HTE721010A9E630", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}"
+
+# Add SSD optimisation
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="OCZ-VERTEX3", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="OCZ-VERTEX3", ATTR{queue/scheduler}="noop"
+
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/scheduler}="noop"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/read_ahead_kb}="256"
+
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/scheduler}="noop"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/read_ahead_kb}="256"
+
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/scheduler}="noop"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/read_ahead_kb}="256"
+
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST240FN0021", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST240FN0021", ATTR{queue/scheduler}="noop"
+
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="SuperMicro_SSD", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="SuperMicro_SSD", ATTR{queue/scheduler}="noop"
+
+# Delete failed disk in cmok
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST_M13FQBL", ENV{ID_SERIAL}=="ST_M13FQBL_QNR_BFW", ATTR{device/delete}="1"
+
+# Enable request merging for NVME devices
+ACTION=="add", SUBSYSTEM=="block", DRIVERS=="nvme", ATTR{queue/nomerges}="1"
+
+# VMware Virtual disk configuration
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/scheduler}="noop"
+
+# Increase readahead on virtio block devices
+ACTION=="add", SUBSYSTEM=="block", DRIVERS=="virtio_blk", ATTR{queue/read_ahead_kb}="4096"
+# Note virtio sets scheduler to none automatically
+
+# QEMU Disk IO tune
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_MODEL}=="QEMU_HARDDISK", ATTR{queue/read_ahead_kb}="4096"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_MODEL}=="QEMU_HARDDISK", ATTR{queue/scheduler}="noop"
+# Vendor is sometimes missing
+
+# Increase default MD raid5/raid6 strip cache + group_thread_cnt
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{MD_LEVEL}=="raid5", ATTR{md/stripe_cache_size}="8192", ATTR{md/group_thread_cnt}="4"
+ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{MD_LEVEL}=="raid6", ATTR{md/stripe_cache_size}="8192", ATTR{md/group_thread_cnt}="4"