when "HP"
package "hponcfg"
+ execute "update-ilo" do
+ action :nothing
+ command "/usr/sbin/hponcfg -f /etc/ilo-defaults.xml"
+ end
+
+ template "/etc/ilo-defaults.xml" do
+ source "ilo-defaults.xml.erb"
+ owner "root"
+ group "root"
+ mode "644"
+ notifies :run, "execute[update-ilo]"
+ end
+
package "hp-health" do
action :install
notifies :restart, "service[hp-health]"
+ only_if { node[:lsb][:release].to_f < 22.04 }
end
service "hp-health" do
action [:enable, :start]
supports :status => true, :restart => true
+ only_if { node[:lsb][:release].to_f < 22.04 }
end
if product.end_with?("Gen8", "Gen9")
supports :status => false, :restart => true, :reload => false
end
-# Link Layer Discovery Protocol Daemon
package "lldpd"
+
service "lldpd" do
action [:start, :enable]
supports :status => true, :restart => true, :reload => true
end
+ohai_plugin "lldp" do
+ template "lldp.rb.erb"
+end
+
+%w[bus cache dimm iomca page socket-memory unknown].each do |trigger|
+ file "/etc/mcelog/#{trigger}-error-trigger.local" do
+ action :delete
+ end
+end
+
+service "mcelog" do
+ action [:stop, :disable]
+end
+
+package "mcelog" do
+ action :purge
+end
+
tools_packages = []
status_packages = {}
when "mpt2sas", "mpt3sas"
tools_packages << "sas2ircu"
status_packages["sas2ircu-status"] ||= []
- when "megaraid_mm"
- tools_packages << "megactl"
- status_packages["megaraid-status"] ||= []
when "megaraid_sas"
tools_packages << "megacli"
status_packages["megaclisas-status"] ||= []
systemd_service "cciss-vol-statusd" do
description "Check cciss_vol_status values in the background"
exec_start "/usr/local/bin/cciss-vol-statusd"
+ nice 10
private_tmp true
protect_system "full"
protect_home true
end
end
-%w[cciss-vol-status mpt-status sas2ircu-status megaraid-status megaclisas-status aacraid-status].each do |status_package|
+%w[cciss-vol-status mpt-status sas2ircu-status megaclisas-status aacraid-status].each do |status_package|
if status_packages.include?(status_package)
package status_package
[]
end
+unless nvmes.empty?
+ package "nvme-cli"
+end
+
intel_nvmes = nvmes.select { |pci| pci[:vendor_name] == "Intel Corporation" }
if !intel_ssds.empty? || !intel_nvmes.empty?
package "unzip"
- intel_mas_tool_version = "1.9"
- intel_mas_package_version = "#{intel_mas_tool_version}.147-0"
+ intel_mas_tool_version = "1.10"
+ intel_mas_package_version = "#{intel_mas_tool_version}.155-0"
remote_file "#{Chef::Config[:file_cache_path]}/Intel_MAS_CLI_Tool_#{intel_mas_tool_version}_Linux.zip" do
- source "https://downloadmirror.intel.com/30556/eng/intel-mas-cli-tool-linux-#{intel_mas_tool_version.gsub('.', '-')}.zip"
+ source "https://downloadmirror.intel.com/646992/Intel_MAS_CLI_Tool_Linux_#{intel_mas_tool_version}-v2.zip"
end
execute "#{Chef::Config[:file_cache_path]}/Intel_MAS_CLI_Tool_#{intel_mas_tool_version}_Linux.zip" do
end
end
-template "/etc/modules" do
- source "modules.erb"
- owner "root"
- group "root"
- mode "644"
+file "/etc/modules" do
+ action :delete
end
-service "kmod" do
- action :nothing
- subscribes :start, "template[/etc/modules]"
+node[:hardware][:modules].each do |module_name|
+ kernel_module module_name do
+ action :install
+ not_if { kitchen? }
+ end
+end
+
+node[:hardware][:blacklisted_modules].each do |module_name|
+ kernel_module module_name do
+ action :blacklist
+ end
end
if node[:hardware][:watchdog]
notifies :run, "execute[remount-dev-shm]"
end
end
+
+prometheus_collector "ohai" do
+ interval "15m"
+end