X-Git-Url: https://git.openstreetmap.org./chef.git/blobdiff_plain/73c87352dac93db7903c8a4258e1615f403abe84..a0aaf12636f979b4fbb9a6350cbf770cacae5361:/cookbooks/devices/templates/default/udev.rules.erb diff --git a/cookbooks/devices/templates/default/udev.rules.erb b/cookbooks/devices/templates/default/udev.rules.erb index a3c43a531..be9903891 100644 --- a/cookbooks/devices/templates/default/udev.rules.erb +++ b/cookbooks/devices/templates/default/udev.rules.erb @@ -1,14 +1,15 @@ # DO NOT EDIT - This file is being maintained by Chef # HP Smart Array configuration -ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/scheduler}="noop" -ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/nr_requests}="512" -ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/read_ahead_kb}="4096" -ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/rq_affinity}="2" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/scheduler}="noop" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/nr_requests}="512" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/rq_affinity}="2" -# VMware Virtual disk configuration -ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/read_ahead_kb}="4096" -ACTION=="add", SUBSYSTEM=="block", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/scheduler}="noop" +# Dell PERC H710 tune +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/scheduler}="deadline" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/nr_requests}="512" <% node[:devices].each do |name,device| -%> @@ -31,14 +32,69 @@ ACTION=="add", SUBSYSTEM=="block", ENV{ID_BUS}=="<%= device[:bus] %>", ENV{ID_SE <% end -%> <% end -%> +# Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168/8411 PCI Express Gigabit Ethernet Controller +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x10ec", ATTRS{device}=="0x8168", RUN+="/sbin/ethtool -K $name tso off gso off" + +# Ethernet controller: Mellanox Technologies MT27710 Family [ConnectX-4 Lx] +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x15b3", ATTRS{device}=="0x1015", RUN+="/sbin/ethtool -G $name rx 8192 tx 8192" + +# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet +# Hewlett-Packard Company NC382i Integrated Multi-port PCI Express Gigabit Server Adapter +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1639", RUN+="/sbin/ethtool -G $name rx 2040" +# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme II BCM5708 Gigabit Ethernet +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x164c", RUN+="/sbin/ethtool -G $name rx 2040" +# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe +# Hewlett-Packard Company Ethernet 1Gb 4-port 331i Adapter +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1657", RUN+="/sbin/ethtool -G $name rx 2047" +# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5721 Gigabit Ethernet PCI Express +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1659", RUN+="/sbin/ethtool -G $name rx 511" +# Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5720 2-port Gigabit Ethernet PCIe +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x165f", RUN+="/sbin/ethtool -G $name rx 2047" + +# Ethernet controller: Intel Corporation 82571EB/82571GB Gigabit Ethernet Controller D0/D1 (copper applications) +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x105e", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation 80003ES2LAN Gigabit Ethernet Controller (Copper) +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1096", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation 82575EB Gigabit Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10a7", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" # Disable scatter-gather offload for HP NC362i network controllers SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10c9", ATTRS{subsystem_vendor}=="0x103c", ATTRS{subsystem_device}=="0x323f", RUN+="/sbin/ethtool -K $name gso off tso off sg off gro off" - +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10c9", ATTRS{subsystem_vendor}=="0x103c", ATTRS{subsystem_device}=="0x323f", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation 82574L Gigabit Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10d3", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" # Fix Power Saving Bug on Intel 82574L and Intel 82583 network controllers SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10d3", RUN+="/usr/local/bin/fixeep-82574_83.sh $name" SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10f6", RUN+="/usr/local/bin/fixeep-82574_83.sh $name" SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x150c", RUN+="/usr/local/bin/fixeep-82574_83.sh $name" +# Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+ Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10fb", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation 82580 Gigabit Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x150e", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation I350 Gigabit Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1521", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation Ethernet Controller 10-Gigabit X540-AT2 +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1528", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation I210 Gigabit Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1533", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation I211 Gigabit Network Connection +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1539", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03) +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x157b", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation Ethernet Controller 10G X550T +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1563", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GBASE-T +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1586", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GBASE-T +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x15ff", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation Ethernet Connection I354 (rev 03) +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1f41", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" +# Ethernet controller: Intel Corporation Ethernet Connection X722 for 10GBASE-T +SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x37d2", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096" + +# Disable Firmware Based LLDP handler +SUBSYSTEM=="net", ACTION=="add", ENV{INTERFACE}=="*", DRIVERS=="i40e", RUN+="/sbin/ethtool --set-priv-flags $name disable-fw-lldp on" + # Workaround unreliable Western Digital WD RE3/RE4 disks (ATA only) # Set sufficent Linux subsystem timeout and fix severe NCQ performance issue ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD5002ABYS-02B1B0", ATTR{device/timeout}="90", ATTR{device/queue_depth}="1", ATTR{queue/nr_requests}="256" @@ -58,9 +114,47 @@ ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="HGST_HTS725050A7E630", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}" ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="HGST_HTE721010A9E630", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}" +# Add SSD optimisation +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="OCZ-VERTEX3", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="OCZ-VERTEX3", ATTR{queue/scheduler}="noop" + +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/scheduler}="noop" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/read_ahead_kb}="256" + +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/scheduler}="noop" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/read_ahead_kb}="256" + +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/scheduler}="noop" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/read_ahead_kb}="256" + +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST240FN0021", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST240FN0021", ATTR{queue/scheduler}="noop" + +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="SuperMicro_SSD", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="SuperMicro_SSD", ATTR{queue/scheduler}="noop" + +# Delete failed disk in cmok +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST_M13FQBL", ENV{ID_SERIAL}=="ST_M13FQBL_QNR_BFW", ATTR{device/delete}="1" + # Enable request merging for NVME devices ACTION=="add", SUBSYSTEM=="block", DRIVERS=="nvme", ATTR{queue/nomerges}="1" +# VMware Virtual disk configuration +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/scheduler}="noop" + # Increase readahead on virtio block devices ACTION=="add", SUBSYSTEM=="block", DRIVERS=="virtio_blk", ATTR{queue/read_ahead_kb}="4096" # Note virtio sets scheduler to none automatically + +# QEMU Disk IO tune +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_MODEL}=="QEMU_HARDDISK", ATTR{queue/read_ahead_kb}="4096" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_MODEL}=="QEMU_HARDDISK", ATTR{queue/scheduler}="noop" +# Vendor is sometimes missing + +# Increase default MD raid5/raid6 strip cache + group_thread_cnt +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{MD_LEVEL}=="raid5", ATTR{md/stripe_cache_size}="8192", ATTR{md/group_thread_cnt}="4" +ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{MD_LEVEL}=="raid6", ATTR{md/stripe_cache_size}="8192", ATTR{md/group_thread_cnt}="4"