]> git.openstreetmap.org Git - chef.git/blob - cookbooks/devices/templates/default/udev.rules.erb
Remove cleanup code
[chef.git] / cookbooks / devices / templates / default / udev.rules.erb
1 # DO NOT EDIT - This file is being maintained by Chef
2
3 # HP Smart Array configuration
4 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/scheduler}="noop"
5 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/nr_requests}="512"
6 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/read_ahead_kb}="4096"
7 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="HP", ENV{ID_MODEL}=="LOGICAL_VOLUME", ATTR{queue/rq_affinity}="2"
8
9 # Dell PERC H710 tune
10 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/read_ahead_kb}="4096"
11 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/scheduler}="deadline"
12 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="DELL", ENV{ID_MODEL}=="PERC_H710", ATTR{queue/nr_requests}="512"
13
14 <% node[:devices].each do |name,device| -%>
15
16 # <%= device[:comment] %>
17 <% if device[:type] == "block" -%>
18 <% if device[:owner] -%>
19 SUBSYSTEM=="block", ENV{ID_BUS}=="<%= device[:bus] %>", ENV{ID_SERIAL}=="<%= device[:serial] %>", OWNER="<%= device[:owner] %>"
20 <% end -%>
21 <% if device[:group] -%>
22 SUBSYSTEM=="block", ENV{ID_BUS}=="<%= device[:bus] %>", ENV{ID_SERIAL}=="<%= device[:serial] %>", GROUP="<%= device[:group] %>"
23 <% end -%>
24 <% if device[:mode] -%>
25 SUBSYSTEM=="block", ENV{ID_BUS}=="<%= device[:bus] %>", ENV{ID_SERIAL}=="<%= device[:serial] %>", MODE="<%= device[:mode] %>"
26 <% end -%>
27 <% if device[:attrs] -%>
28 <% device[:attrs].each do |name,value| -%>
29 ACTION=="add", SUBSYSTEM=="block", ENV{ID_BUS}=="<%= device[:bus] %>", ENV{ID_SERIAL}=="<%= device[:serial] %>", ATTR{<%= name %>}="<%= value %>"
30 <% end -%>
31 <% end -%>
32 <% end -%>
33 <% end -%>
34
35 # Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168/8411 PCI Express Gigabit Ethernet Controller
36 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x10ec", ATTRS{device}=="0x8168", RUN+="/sbin/ethtool -K $name tso off gso off"
37
38 # Ethernet controller: Mellanox Technologies MT27710 Family [ConnectX-4 Lx]
39 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x15b3", ATTRS{device}=="0x1015", RUN+="/sbin/ethtool -G $name rx 8192 tx 8192"
40
41 # Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme II BCM5709 Gigabit Ethernet
42 # Hewlett-Packard Company NC382i Integrated Multi-port PCI Express Gigabit Server Adapter
43 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1639", RUN+="/sbin/ethtool -G $name rx 2040"
44 # Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme II BCM5708 Gigabit Ethernet
45 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x164c", RUN+="/sbin/ethtool -G $name rx 2040"
46 # Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
47 # Hewlett-Packard Company Ethernet 1Gb 4-port 331i Adapter
48 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1657", RUN+="/sbin/ethtool -G $name rx 2047"
49 # Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5721 Gigabit Ethernet PCI Express
50 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x1659", RUN+="/sbin/ethtool -G $name rx 511"
51 # Ethernet controller: Broadcom Inc. and subsidiaries NetXtreme BCM5720 2-port Gigabit Ethernet PCIe
52 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x14e4", ATTRS{device}=="0x165f", RUN+="/sbin/ethtool -G $name rx 2047"
53
54 # Ethernet controller: Intel Corporation 82571EB/82571GB Gigabit Ethernet Controller D0/D1 (copper applications)
55 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x105e", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
56 # Ethernet controller: Intel Corporation 80003ES2LAN Gigabit Ethernet Controller (Copper)
57 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1096", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
58 # Ethernet controller: Intel Corporation 82575EB Gigabit Network Connection
59 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10a7", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
60 # Disable scatter-gather offload for HP NC362i network controllers
61 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10c9", ATTRS{subsystem_vendor}=="0x103c", ATTRS{subsystem_device}=="0x323f", RUN+="/sbin/ethtool -K $name gso off tso off sg off gro off"
62 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10c9", ATTRS{subsystem_vendor}=="0x103c", ATTRS{subsystem_device}=="0x323f", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
63 # Ethernet controller: Intel Corporation 82574L Gigabit Network Connection
64 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10d3", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
65 # Fix Power Saving Bug on Intel 82574L and Intel 82583 network controllers
66 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10d3", RUN+="/usr/local/bin/fixeep-82574_83.sh $name"
67 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x10f6", RUN+="/usr/local/bin/fixeep-82574_83.sh $name"
68 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x150c", RUN+="/usr/local/bin/fixeep-82574_83.sh $name"
69
70 # Ethernet controller: Intel Corporation 82580 Gigabit Network Connection
71 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x150e", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
72 # Ethernet controller: Intel Corporation I350 Gigabit Network Connection
73 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1521", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
74 # Ethernet controller: Intel Corporation Ethernet Controller 10-Gigabit X540-AT2
75 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1528", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
76 # Ethernet controller: Intel Corporation I210 Gigabit Network Connection
77 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1533", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
78 # Ethernet controller: Intel Corporation I211 Gigabit Network Connection
79 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1539", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
80 # Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
81 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x157b", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
82 # Ethernet controller: Intel Corporation Ethernet Controller 10G X550T
83 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1563", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
84 # Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GBASE-T
85 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x1586", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
86 # Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GBASE-T
87 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x15ff", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
88 # Ethernet controller: Intel Corporation Ethernet Connection X722 for 10GBASE-T
89 SUBSYSTEM=="net", ACTION=="add", ATTRS{vendor}=="0x8086", ATTRS{device}=="0x37d2", RUN+="/sbin/ethtool -G $name rx 4096 tx 4096"
90
91 # Workaround unreliable Western Digital WD RE3/RE4 disks (ATA only)
92 # Set sufficent Linux subsystem timeout and fix severe NCQ performance issue
93 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD5002ABYS-02B1B0", ATTR{device/timeout}="90", ATTR{device/queue_depth}="1", ATTR{queue/nr_requests}="256"
94 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD1002FBYS-02A6B0", ATTR{device/timeout}="90", ATTR{device/queue_depth}="1", ATTR{queue/nr_requests}="256"
95 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD1003FBYX-01Y7B0", ATTR{device/timeout}="90", ATTR{device/queue_depth}="1", ATTR{queue/nr_requests}="256"
96 # Disable Disk Write Cache, Set AAM and Power Management correctly
97 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD1002FBYS-02A6B0", RUN+="/sbin/hdparm -q -W0 -q -M254 $env{DEVNAME}"
98 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD1003FBYX-01Y7B0", RUN+="/sbin/hdparm -q -W0 -q -M254 -q -B254 $env{DEVNAME}"
99
100 # Set Disks TLED / SCT Error Recovery Control
101 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD1002FBYS-02A6B0", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,70,70 $env{DEVNAME}"
102 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD1003FBYX-01Y7B0", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,70,70 $env{DEVNAME}"
103 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD5000AAKS-00A7B0", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,70,70 $env{DEVNAME}"
104 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="WDC_WD2000FYYZ-01UL1B2", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,70,70 $env{DEVNAME}"
105 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="TOSHIBA_DT01ACA300", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,70,70 $env{DEVNAME}"
106 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST31000340NS", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}"
107 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="HGST_HTS725050A7E630", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}"
108 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="HGST_HTE721010A9E630", RUN+="/usr/sbin/smartctl -q errorsonly -l scterc,100,100 $env{DEVNAME}"
109
110 # Add SSD optimisation
111 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="OCZ-VERTEX3", ATTR{queue/read_ahead_kb}="4096"
112 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="OCZ-VERTEX3", ATTR{queue/scheduler}="noop"
113
114 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/read_ahead_kb}="4096"
115 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/scheduler}="noop"
116 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_840_PRO_*", ATTR{queue/read_ahead_kb}="256"
117
118 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/read_ahead_kb}="4096"
119 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/scheduler}="noop"
120 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_850_PRO_*", ATTR{queue/read_ahead_kb}="256"
121
122 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/read_ahead_kb}="4096"
123 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/scheduler}="noop"
124 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="Samsung_SSD_860_PRO_*", ATTR{queue/read_ahead_kb}="256"
125
126 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST240FN0021", ATTR{queue/read_ahead_kb}="4096"
127 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST240FN0021", ATTR{queue/scheduler}="noop"
128
129 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="SuperMicro_SSD", ATTR{queue/read_ahead_kb}="4096"
130 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="SuperMicro_SSD", ATTR{queue/scheduler}="noop"
131
132 # Delete failed disk in cmok
133 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_BUS}=="ata", ENV{ID_MODEL}=="ST_M13FQBL", ENV{ID_SERIAL}=="ST_M13FQBL_QNR_BFW", ATTR{device/delete}="1"
134
135 # Enable request merging for NVME devices
136 ACTION=="add", SUBSYSTEM=="block", DRIVERS=="nvme", ATTR{queue/nomerges}="1"
137
138 # VMware Virtual disk configuration
139 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/read_ahead_kb}="4096"
140 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_VENDOR}=="VMware", ENV{ID_MODEL}=="Virtual_disk", ATTR{queue/scheduler}="noop"
141
142 # Increase readahead on virtio block devices
143 ACTION=="add", SUBSYSTEM=="block", DRIVERS=="virtio_blk", ATTR{queue/read_ahead_kb}="4096"
144 # Note virtio sets scheduler to none automatically
145
146 # QEMU Disk IO tune
147 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_MODEL}=="QEMU_HARDDISK", ATTR{queue/read_ahead_kb}="4096"
148 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{ID_MODEL}=="QEMU_HARDDISK", ATTR{queue/scheduler}="noop"
149 # Vendor is sometimes missing
150
151 # Increase default MD raid5/raid6 strip cache + group_thread_cnt
152 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{MD_LEVEL}=="raid5", ATTR{md/stripe_cache_size}="8192", ATTR{md/group_thread_cnt}="4"
153 ACTION=="add", SUBSYSTEM=="block", ENV{DEVTYPE}=="disk", ENV{MD_LEVEL}=="raid6", ATTR{md/stripe_cache_size}="8192", ATTR{md/group_thread_cnt}="4"